logo-1
Whatsapp:+
  • RF High Frequency & 980nm Diode Laser Vascular Removal Machine
  • RF High Frequency & 980nm Diode Laser Vascular Removal Machine
  • RF High Frequency & 980nm Diode Laser Vascular Removal Machine
  • RF High Frequency & 980nm Diode Laser Vascular Removal Machine
  • RF High Frequency & 980nm Diode Laser Vascular Removal Machine
  • RF High Frequency & 980nm Diode Laser Vascular Removal Machine
Share to:

RF High Frequency & 980nm Diode Laser Vascular Removal Machine

You haven't uploaded the QR code yet.
Please upload the QR code image in the background

Voltage AC
100-240V, 50/60Hz
Operation interface
8.0 inch touch screen
Laser wavelength
980nm
Output frequency
13.56MHz
Aiming Beam
650nm
Working Mode
Continuous mode/Pulse mode
Output waveform
Sine wave
Laser core
RF high frequency core and
diode Fiber-optic coupling
Pulse width
15ms—100ms
Laser Power 15w +RF, 20w +RF, 30W+RF
Input power/Output Power
60W/45W
Machine Model JRBS-V
Sterile needle specifications
0.14x5mm
Length of Fiber
2m
Package/Weight 46x44x34cm/13kg

Quantity:


RF High Frequency vascular removal
The RF high frequency vascular removal machine uses professional painless 13.56 million Hz high-frequency technology, using soft needle wire to conduct the released energy below the skin surface,break the hemoglobin in the blood vessels into small molecules and be absorbed by the skin tissue itself. the coagulated tissue will fall off within 3-7 days, regenerating new skin tissue, to achieve the effect of one-time eradication of spider vein. The diameter of the treatment end is only 0.1mm. The damage to the epidermis during treatment is negligible.  the treatment process is comfortable and fast, and does not affect the normal life and work of the patient.
980nm laser vein removal
980nm laser is the optimum absorption spectrum of porphyrin vascular cells. Vascular cells absorb the high-energy laser of 980nm wavelength, solidification occurs, and finally dissipated. To overcome the traditional laser treatment redness large area of burning the skin, professional design hand-piece, enabling the 980nm laser beam is focused onto a 0.2-0.5mm diameter range, in order to enable more focused energy to reach the target tissue, while avoiding burn the surrounding skin tissue.Laser can stimulate the dermal collagen growth while vascular treatment, increase epidermal thickness and density, so that the small blood vessels are no longer exposed, at the same time, the skin's elasticity and resistance is also significantly enhanced.
Ice hammer
Ice compress hammer can reduce the temperature of local tissues in the body, promote the tension of sympathetic nerves, shrink blood vessels, and reduce the sensitivity of tissues to pain.Laser treatment should be done immediately ice compress, and the postoperative swelling peak period is within 48 hours. At this time, ice compress can reduce swelling and pain to the greatest extent and shrink blood vessels. 


1. ASI grade HF / diode laser power tube, no power loss during continuous operation.
2. 13.56MHz ± 130V sine wave output, real high frequency, no sparks, no skin damage.
3. Continuous or pulse dual output mode selection.No offset in different impedance environments.
4.The 980nm laser diode output power is constant and there is no large-scale drift, which ensures the consistency of operation.
5.Professional treatment pen needles ensure immediate closure of blood capillaries and good protectionof the epidermis.
6.Configure imported core boards to ensure long life and stability.


980nm laser vein removal machine with five focusing rings are used to adjust the spot size, the minimum spot is 0.2mm, 0.5mm,1.0mm,2.0mm and the maximum spot 3mm. In practice, the most commonly usedThe instrument comes with a 0.2mm focus ring,laser tips choose according to the specific vein treatment situation.


RF vein removal operate

980nm laser spider vascular removal operate

980nm diode laser treat steps
1) Before powering on, take off the protective cover of the fiber optic handpiece. After powering on, do not look directly at the handpiece treatment head with the naked eye. The 980nm output light is invisible light, and the damage to the eyes is irreversible. Wear laser glasses or goggles for protection.
2) Connect the power cord, click the power button, do not apply gel, etc.;
3) Parameter setting,Set each parameter in Pause (standby state). (After the Start button is activated, the setting parameter is invalid).
Power Adjustment: Click the (+) or (-) button in the energy area to adjust the energy output. The highest value is 20W, and the commonly recommended value is 6W-12W.
Pulse width setting: Click the (+) or (-) button in the pulse width area to adjust the pulse width value. The highest value is 100ms, and the commonly recommended value is 50ms.
Frequency setting: Click the (+) or (-) button in the frequency area to adjust the frequency value. The highest value is 5 Hz, and the commonly recommended value is 2 Hz.
Current count: The displayed value is the number of lasers used after the current startup. Automatically reset when power off.
Total count: The displayed value is the total number of lasers used by the machine, which will not be cleared after shutdown. If you want to clear it, you can long press the displayed value in standby mode.
Indicator light setting: Click the indicator light button to adjust the brightness of the indicator light, the third gear is the brightest. The indicator light only has the effect of aiming, not treating. When treating red blood cells, you can use the first gear. If it is too bright, you will not be able to see the red blood cells.
4) After the setting is completed, click the start button, step on the foot switch, and start the work treatment.
Note: The time for each treatment of red blood should not exceed 15 minutes. Do not repeat the operation for the same point and the same red blood capillary, but move the laser pointer or RF needle forward one point at a time. Since the red blood capillaries have two structures, the trunk and the branch, the operator must first start with the small lesion branch capillaries, and then make the lesion trunk capillaries. It is normal to feel a little tingling during the operation, and there is no need to apply numbing cream.




1) Vascular removal: face, arms, legs and the whole body.
2) Pigment lesions treatment: speckle, age spots, sunburn,pigmentation removal. 
3) Facial red vascular removal, vascular lesion treatment, varicose veins treatment.
4) Blood spider clearance, spider veins removal,vein removal.
5) Vascular clearance ,vascular lesions therapy. 
6) Acne treatment, redness treatment.


Package list:
1 beauty machine host    1 ice handle    1 laser fiber optic hand tool    1 high frequency handle
10 disposable needles   2 red blood plugs (hook/straight fork)    5 focusing rings   1 aluminum box
1 eye mask and laser glasses    1 foot switch    1 beauty machine manual    1 power cord

1, Are there risks to RF therapy?
Radio frequency vascular removal is performed on the surface of the skin, selectively and targeted elimination of the skin surface will not affect normal tissues, after treatment can return to a normal state after a period of time, without leaving scars, not Will be pigmented. 

 2, Are there any precautions for the operator?
RF operation is very simple and requires very little operator. Just aim at the vascular and operate little by little.
Pay attention:Use a disposable needle to move little by little when vascular removal. Do not repeat the operation.Each point does not exceed 2 seconds.

3,What are the procedures for large-area vascular?
Because red blood filaments have both a trunk and a branch structure, the operator must first startwith small diseased branch capillaries, and then make the diseased main capillaries.For large areas of vascular, it is recommended to complete it in several times. Do less for the first time,observe the skin repair. Record the treatment parameters and build a file for the customer.
Operate other parts after one week. If the thick red blood cells are not removed for the first time, repeat the treatment at least two weeks later.

4, How does the treatment process feel and do I need to apply anesthetic?
A slight tingling sensation during operation is normal and does not require anaesthesia.

5, Is redness and swelling after treatment, how to repair care?
Generally, no special care is required after vascular removing, and the instrument will not damage normal tissues and will not leave scars. However, in order to achieve better treatment results, the following points should be noted:
(1)If it is normal to have a slight scab after the operation, do not remove it artificially, you must wait for it to fall off naturally.
(2)Slight redness in the treated area after surgery is normal, and the ice hammer provided with the instrument can be used to cool down. See the instructions for specific use.
(3)After vascular removing, you cannot use a irritating facial cleanser. It is recommended to wash your face after three days. You can use clean water. The temperature of the water should not be too cold and hot, and you should not use cold and hot water alternately,and reduce the number of times you wash your face every day.
(4)Do not use exfoliating cosmetics, do not use sauna, do not use inferior cosmetics and peeling products containing hormones.
(5)Try to eat less irritating foods such as beef and mutton, seafood, wine, coffee, etc. Do not make up often to make your skin fully rested;
(6)You can use the computer to work normally, but pay attention to sun protection and pay attention to hydration

Need More Info

Don't worry we won't spam you

< a href='https://www.ttkefu.com' >在线客服系统