Whatsapp:+008615200089972
  • 640nm IPL SHR OPT fast permanent hair removal machine
  • 640nm IPL SHR OPT fast permanent hair removal machine
  • 640nm IPL SHR OPT fast permanent hair removal machine
  • 640nm IPL SHR OPT fast permanent hair removal machine
  • 640nm IPL SHR OPT fast permanent hair removal machine
Share to:

640nm IPL SHR OPT fast permanent hair removal machine

You haven't uploaded the QR code yet.
Please upload the QR code image in the background

Voltage
110V-240V/50-60Hz
Model JIPL-5
Operation interface
8.4-inch touch color screen
Power 1200W or 2000W
Spot size 12x30mm or 15x50mm
Xenon lamp
China lamp, UK lamp, Germany lamp
Energy
1-26J/cm2(SHR)
Filter 480nm,530nm,560nm,590nm,640nm
Pulse Width
1-9.9ms
Refrigeration system
air cooling, water cooling, semiconductor refrigeration
Fuction

fast hair removal , acne removal , vascular lesions etc

Certificate
CE , ISO
Spot crystal Sapphire crystal or Quartz crystal
Machine material
ABS
packing weight 42 kg

Quantity:


    Jelsys IPL SHR machine system emits a broad spectrum of intense pulsed light through a small, smooth hand piece.The light is placed over the skin gently. Cut-off filters (five different filters for option) in the hand piece change the wavelength range allowing it to be optimized for different applications and skin types. The light penetrates the tissue and is absorbed by either the blood when treating vascular lesions or the melanin when treating pigmented lesions or for hair removal and then damaging them. The body's natural processes then remove the injured tissue giving the skin a more even and youthful appearance. And at the same time, production of the collagen in dermis will be prompted to increase the flexibility of the skin and get rid of fine wrinkles.

5 filters for IPL SHR laser handle functions:
480nm~1200nm: acne treatment
530nm~1200nm: skin rejuvenation 
590nm~1200nm: skin whitening, pigment treatment, spider vein treatment
640nm~1200nm: hair removal for fair to yellow skin
690nm~1200nm: hair removal for dark skin




Jelsys IPL E-Light Laser Treatment Theory :

1. The Theory of Permanent Hair Removal: 
The theory is the energy from IPL acting on the 15mm depth of surface, plus RF to prevent hair growth without hurting the sweat glands. Generally, there are 3 cycle of hair growth: Growth Phase, Maturity Phase, Dormancy Phase, and the treatment will be most effectively in hair's Growth Phase, so patients need do the treatment 3-4 times to achieve permanent hair removal.

2. The theory of speckles/ freckle/age spot/sun-induced freckles removal:
To extract and decompose a plenty of pigment from skin depth by taking advantage of IPL laser, and to impe the pigment's discharge from Lymphatic by taking advantage of RF.

 3.The theory of Skin whitening / face lifting / rejuvenating, pore shrinking, and wrinkles removal:
To stimulate the Fiber-forming Tissue of the skin's Dermal Layer, promote collagen's forming, and accelerate cell tissue's rearrangement by using IPL+RF, so as to achieve the effect of skin whitening, skin rejuvenating, pore shrinking, and wrinkles removal.

 4.The theory of blood vessel/ erythema removal/tattoo removal:
The Skin Lesions Capillaries can be solidified by the light of DPL, and the RF can improve IPL function through locking the lesion, so the blood vessel will be removed by Skin and Lymph System's metabolism. 



Jelsys beauty machine Advantages:
1.Intelligent control system, Multiple languages to choose ,easy to operate, stable ipl shr laser energy control,good effect
2.Big power supply 2000W, it supports continouse work time more than 10-14 hours. 
3.Perfect cooling system: Japanese semiconductor +water + air + cooling gel, And the sapphires skin cooling temperature can be in -4-10 ℃ 
4.USA crystal gem, It make sure the shot pulse 99.9% purity quotient. 
5.Low cost with highest quality. UK lamp ,300000 shots life.
6.Metal inner metal structures Electronic connector and high-end CPC connectors avoiding any damage of the inner wires when pulling hardly.







Applications:
1. Permanent hair removal: covers all kinds of hair and skin type, limbs hair, axillary hair, beard, lip hair, etc. 
2. Vascular lesions: telangiectasis, bottle nose, varicosity, rosacea, spider vein 
3. Pigmentation : freckle/old spots/chloasma/age pigments removal, sun spots/ chorioplaque removal, eliminating dotted or massive chromatosis 
4. Skin Rejuvenation: improve coarse pore,skin rough and dim complexion; make the skin white, color and luster uniform, and skin restoring elastic 
5. Wrinkle removal :Removal of forehead wrinkles, crow's feet, nasal furrow wrinkles, neck wrinkle 
6. Acne treatment : Anaphylatic pox, acne, acne scar, blackhead


    1. Use a medical skin repair mask after surgery. If there is a significant burning sensation, an ice pack can be used.


    2. Pigmentation and hypopigmentation may occur in individual patients, which can be recovered after a few months, and it will take longer for very few patients.

    3. Some people will have a slight scab after the treatment, which will usually fall off within a week. Do not pick it off by yourself.

    4. After treatment, it is necessary to strengthen the skin moisturizing to soothe and calm the skin.

    5. Avoid using irritating skin care products containing fruit acid, A acid, high-concentration vitamin C, salicylic acid, alcohol, etc. within one week after treatment.

    6. Strengthen sun protection, preferably use sunscreen with SPF30 or even SPF50 or above, and do physical sunscreen when going out, such as holding an umbrella.

    7. It takes several times in a row to achieve the desired effect.


      When installing the handle, it is required to tighten the connections of the two water pipes and the three power cords at the joints and not connect them virtually, otherwise it will easily cause a short circuit and burn the power head and cause the instrument to malfunction.
     1. The connection of the water pipe should not leak.
     2. After each use, the handle sapphire crystal should be cleaned to prevent damage.
     3. Each instrument should be filled with water, replace the water every ten to fifteen days (preferably using deionized water), drain the water in the water tank and add water.
     4. If the instrument is newly filled with water or turned on after changing the water, the key should be turned on and off the instrument repeatedly 2-3 times, and then press the keys in sequence to adjust the parameter keys.
    5. After each time the key is turned on, wait for the water in the water tank to circulate for one minute and then press the pre-ignition key (turn on the light) to prevent damage to the IPL xenon lamp.